|
¤ý´ã´çÀÚ |
|
¤ýȨÆäÀÌÁö |
http://www.photosensor.co.kr |
¤ýLink#1 |
speed1.gif
(Down:79) |
¤ý°³¹ß(ÆǸÅ)ȸ»ç |
¿ì¼ºÀÏ·ºÆ®·¹À̵å |
¤ýÁÖ¼Ò | ¼¿ïƯº°½Ã ±¸·Î±¸ ±¸·Îº»µ¿ 1258 (Áß¾ÓÀ¯Åë´ÜÁö °¡µ¿ 3325È£) |
¤ýÀüÈ | 02-2686-7314 |
¤ýFAX | 02-2686-7316 |
¤ýÀÀ¿ëºÐ¾ß | Àü±âÀüÀÚ, ±â°è |
|
|
¼ÓµµÃøÁ¤¼¾¼(VLM 200A)
Speed measuring range up to 3000 m/min
Measuring distances 170,185,240,330 mm
Application .. Lengths- and velocity- measurement on almost all surfaces
Evaluation .. Processing unit for length-calculation
Accuracy .. 0.1 %
Repeatability .. better than 0.1 % in the range of 185 ¡¾ 7,5 mm
Working distance .. 185 ¡¾ 7.5 mm
widen .. 185 ¡¾ 15 mm, accuracy 0.2 %
Velocity range .. 0.07 up to 6.7 m/s (4 up to 400 m/min)
(on customers demand) .. widen 0.14 up to 13.3 m/s (8 up to 800 m/min)
Length range .. internal range for length measurement until 200 km
Detector / measurement principle .. CCD-line / spatial filter principle
Lighting .. white light, halogen lamp 10 W
Programming interface .. RS 232 (opto isolated)
Opto isolated outputs .. OUT1, OUT2, OUT3
function .. OUT1, OUT2: pulse output, 2 phases pulse encoder emulation
OUT3: signal status
frequency of pulse output .. 1 Hz - 7 kHz (max. +0,2 % measuring error at 7 kHz)
(optional high resolution pulse output available)
type / max. output current .. npn open collector / 40 mA
Opto isolated inputs .. IN1, IN2
function .. external direction signal and trigger signal
(for signals ¡¾20 mA, 0/20 mA or 0/24 V, Ri approx. 1 kOhm)
LOW-level .. -40 up to +0,3 mA
HIGH-level .. +2 up to +40 mA
Power supply .. 230 V / 50 Hz optional 115 V / 60 Hz or 24 V / DC
Power consumption .. < 50 W
Temperature range .. 0 up to 50 ¡ÆC (0 up to 120 ¡ÆF)
Protection type .. IP 65
Weight .. approx. 5,8 kg
Electrically Magnetically Agreeableness .. Industrial standard corresponding to CE 4)
Case sizes without connectors .. 360 mm x 160 mm x 90 mm
Options
Analog output IF1 4 up to 20 mA or 0 up to 20 mA (16 Bit, opto isolated); various digitally interfaces IF1
(RS485/RS422, RS232, opto isolated); high resolution pulse output IF2 0.4 Hz up to 25 kHz and IF2F up to
500 kHz (2 x 2 pulse, resolution 20 ns); interface carts for Ethernet or Profibus DP; laser light barrier,
automatic direction detection (not for F/S-series), Real Time Clock, counter and displays; mounting
equipment, linear units, protection case, window jet
1) DIN 1319 / ISO 3534, from the measured length value,
2) Conventional type, other types possible
3) all connections are short-circuit proof,Conditions: length 10 m max. voltage 50 V/DC, 36V/AC
4) proof test by accredited institute
|
|
|
¹øÈ£ |
|
½ÅÁ¦Ç°¸í |
°³¹ß(ÆǸÅ)ȸ»ç |
ÀÛ¼ºÀÏ |
Á¶È¸ |
165 |
|
°í¿Â¿ë Ç¥¸é¼¾¼ (S-FH-I)
|
Á¶¼±°èÃø±â |
2004-06-16
|
1501
|
|
164 |
|
Á¤Àü¿ë·®¼¾¼
|
(ÁÖ)ÄÚ¹ßÆ® |
2004-06-15
|
2719
|
|
163 |
|
ÃÊÀ½ÆÄ SENSOR (NPN / Open collector)
|
´ëÇö»ó°ø |
2004-06-14
|
2534
|
|
162 |
|
(À§Ä¡¼¾¼)Temposonics-RF(Analog)
|
¢ßMSK |
2004-06-10
|
2621
|
|
161 |
|
LoadCell Model WG
|
ONDI |
2004-06-09
|
1580
|
|
160 |
|
±¤ÈÀ̹ö½Ä Æ÷Å丶ÀÌÅ©·Î¼¾¼
|
OMRON |
2004-06-08
|
2165
|
|
159 |
|
¼ÓµµÃøÁ¤¼¾¼(VLM 200A)
|
¿ì¼ºÀÏ·ºÆ®·¹À̵å |
2004-06-07
|
2660
|
|
158 |
|
¾ÚÇÁ ºÐ¸®Çü µðÁöÅÐ ¾Ð·Â ¼¾¼
|
(ÁÖ)Çѱ¹ Å°-¿£½º |
2004-06-05
|
1824
|
|
157 |
|
Cable Sensor(Encoder Type)
|
(ÁÖ)¾¾Æ¼¿¡ÀÌÇ÷¯½º |
2004-06-04
|
1427
|
|
156 |
|
±ÙÁ¢¼¾¼(AMP ºÐ¸®Çü) SP-01
|
(ÁÖ)ÇѸ²ÀÚµ¿ |
2004-05-22
|
2672
|
|
10
|
|